POWER UNDER CONTROL
Control panels, generator automation and power quality.
Designed and built in Pune.
Channel Partner To -


From panel to plant
Control panels, power distribution, automation and power quality, from design through commissioning and service.
Our Clients
Explore our solutions.
Control Panel Manufacturing
PCC, MCC, VCB and load management panels, designed and built in-house.
View products 5
Woodward Power Generation
Synchronisation, load sharing and genset control for captive and standby power.
View products 6
Turbine & Turbo Machinery
Governors, actuators and overspeed protection for steam and gas turbines.
View products 7
Power Quality Solutions
Harmonic filtering, power factor correction and on-site power quality audits.
View products 3
SEG Protection Relay
Feeder, generator and transformer protection relays from SEG.
View products 6
Read our case studies.
Explore all case studiesWe bring powerinto sync.
Power questions.
Engineered answers.
Which Woodward controller is right for my generator?
For a single DG set, the easYgen-1000 series (1400, 1600, 1800) is the usual choice. For synchronizing or load sharing, look at the easYgen-2000 (2300, 2500) or 3000 series (3200XT, 3500XT). They work with Cummins and other engines on 12V or 24V DC. Share your generator make, rating and required functions, and we will shortlist the model.
Explore Woodward controllersHow can I start my generator automatically during a power failure?
Use an AMF (Automatic Mains Failure) controller such as the Woodward easYgen-1400, 1600 or 1800. It starts the DG set when the mains fails, transfers the load, and switches back when the mains returns.
View AMF controllersWhy won't my generators synchronize or share load evenly?
Generators must match voltage, frequency and phase before they connect, then split the load fairly. A DG synchronization controller like the easYgen-2300 or 3200XT does both, and the DSLC-2 and MSLC-2 add digital load sharing and grid import/export control. For breaker synchronizing alone, the SPM-D and LS-6XT are options. Wrong settings or an ageing controller are common causes, so tell us what you are seeing.
Explore synchronization controllersCan I replace or repair a failed or obsolete Woodward controller?
Usually, yes. Send the model number and the fault, and we will tell you whether repair makes sense or suggest the current replacement, along with what changes in wiring and settings. As a Woodward Business Partner, we supply genuine units.
Discuss repair or replacementShould I replace my old steam turbine governor with a Woodward 505XT?
If your governor drifts, trips unexpectedly or is hard to get spares for, a 505XT retrofit usually makes sense. We check the turbine, actuator and overspeed protection first, then plan the changeover for your shutdown.
View the Woodward 505XTWhy is my steam turbine speed unstable or slow to respond to load changes?
Common causes are governor settings, a worn actuator or an ageing governor. We inspect the control system before recommending tuning, an actuator replacement or a governor upgrade. Share the turbine type, governor model and recent operating records.
Explore turbine controlsWhich control panels do you make, and can you build to our drawings?
We manufacture DG synchronization, MCC, PCC, VCB, load shedding, PLC, VFD, APFC and hybrid panels at our Wadki facility in Pune. Send your drawings or single-line diagram, and we will review the scope and feasibility.
Explore control panelsWhat is the difference between a PCC and an MCC panel?
A PCC panel receives and distributes the main power. An MCC panel starts and controls motors. Most plants need both. Tell us your loads, and we will size them.
Explore control panelsWhy am I paying power factor penalties, and how do I fix it?
Motors and other inductive loads draw reactive power, which pulls the power factor down. An APFC panel adds capacitors automatically as the load changes. For fast-changing loads, a hybrid panel or an SVG is better. A power quality audit shows which one you need.
Explore power quality solutionsHow do I know if harmonics are a problem, and what is the difference between an AHF and an SVG?
Hot transformers or cables, early capacitor failures and drive faults point to harmonics from VFDs and similar loads. An Active Harmonic Filter (AHF) reduces harmonic distortion, while an SVG manages reactive power. Measure first, so you buy the right one.
Explore power quality solutionsWhat is a load shedding (ILMS) system, and does my plant need one?
When a generator trips or the grid fails, load shedding drops non-essential loads so the essential ones keep running. Plants with captive power or co-gen, like sugar and steel plants, usually need an ILMS. We build these panels and can link them to your DCS or SCADA.
Explore load shedding panelsCan you upgrade our existing power system without replacing everything?
Often, yes. We review your generators, switchgear and controls, keep what is compatible, and upgrade the rest. Send your single-line diagram, generator ratings and a short description of the problem.
Discuss your power systemWhat does your facility management service cover?
Electrical, HVAC, DG sets, BMS/CCTV, plumbing and boiler operations, handled by one team. We serve IT, sugar, MNC and hospital sites.
Explore facility managementWhy does my protection relay keep tripping?
It could be a genuine fault, wrong settings or a wiring problem. Check the trip records and settings first. If the cause is still unclear, send us the relay model and trip history.
Get relay supportWhich protection relay do I need for my generator or panel?
It depends on what you are protecting. Generators typically need overcurrent, reverse power, voltage, frequency and earth-fault protection. We supply Woodward SEG relays and can replace obsolete ones. Share the equipment type, voltage and current ratings.
Explore protection relaysCan't find your question?
Send it to our engineers by phone or email.