Overview
Features
- Full connectivity of up to 32 Generators and 16 LS-5 circuit breaker controls in one application
- Run-up synchronization / Dead Field Paralleling to quickly get several synchronous generators onto the load
- Three-phase true RMS power sensing with Class I accuracy
- Operation modes: AUTO, STOP, MANUAL, and TEST – accessible through faceplate or discrete input
- Breaker control: Slip frequency / phase matching synchronization, open/close control, breaker monitoring
- Load transfer: open / closed transition, interchange, soft loading / unloading, Utility parallel
- Load share and device to device communication over CAN or Ethernet (Redundant possible)
- Remote control via the interface (Modbus TCP, Modbus RTU) and via discrete/analog inputs for adjusting speed, frequency, voltage, power, reactive power, and power factor set points
- Freely configurable PID controllers for various control purposes, such as heating circuit control (CHP applications), water level, fuel level, pressure and / or other process variables
- Direct support to several ECUs: Scania S6, MTU ADEC ECU7/8/9, Volvo EMS2 & EDC4, Deutz EMR2 & EMR3, MAN MFR / EDC7, SISU EEM, Cummins and Woodward EGS02 ECU
- Field ECU support and additional I/O expansion board connectivity through sequencer files
- “System Update” function for online troubleshooting and adding/removing generator sets
- Time / Date synchronization over Simple Network Time Protocol (SNTP)
- Cylinder head/exhaust temperature monitoring (Temperatures come from J1939 or CANopen devices)
- Woodward ToolKit™ software for flexible setup from a single connection to the network. The ToolKit can be accessed either via USB, or via Ethernet, or via CAN ports.
- Multi-lingual capability: English, German, Spanish, French, Italian, Portuguese, Japanese, Chinese, Russian, Turkish, Polish, Slovakian, Finnish, Swedish
Highlights
- Premium genset control for complex paralleling applications of up to 32 gensets and up to 16 MCB/GGB/Tie Breakers in
- Prime Power & Cogeneration (CHP)
- Peak shaving operation
- Emergency operation
- Import/Export operation
- Islanded & Utility parallel operation
- Integrated Generator Group Breaker (GGB) control
- Run-Up Synchronization
- Master or Slave control capability
- Complete engine, generator and utility protection
- Up to 9 communication ports: 3xEthernet, 3xCAN (CANOpen and J1939), RS-485, USB, Interface expansion card
- Customizable logic, HMI screens, and alarms
- Dedicated low-temperature display variants
- UL 61010, UL 6200, CSA, RoHS 2, and marine (ABS, LR) compliance
Details
| Power supply | 12/24 VDC (8 to 40 VDC) |
|---|---|
| Intrinsic consumption | max. 22 W (LT: max.32 W) |
| Ambient temperature (operation) | -20 to 70 °C (LT: -40 to 70 °C) |
| Ambient temperature (storage) | -30 to 80 °C / -22 to 176 °F |
| Measurable alternator windings | 3p-3w, 3p-4w, 3p-4w OD, 1p-2w, 1p-3w |
| Measuring frequency | 50/60 Hz (30 to 85 Hz) |
| Max. power consumption per path | < 0.15 W |
| Setting range | 1 to 32,000 A |
| Accuracy | . Class 1.0 |
| Power Setting Range | . 0.5 to 99,999.9 kW/kvar |
| Discrete inputs | Isolated |
| Input range | .12/24 VDC (8 to 40 VDC) |
| Input resistance | approx. 20 kOhms |
| Relay Outputs | Isolated |
| Contact material | AgCdO |
| Insulation voltage (continuously | 100 VAC/DC |
| Insulation test voltage (1s) | 500 VAC |
| Analog inputs (isolated) | Freely scalable |
| Analog outputs (isolated) | Freely scalable |
| Housing Front panel flush mounting | Plastic housing |
| Front cutout (WxH) | 249 [+1.1] × 183 [+1.0] mm |
| Front | Insulating surface |
| Housing Back panel mounting | Powder Coated Sheet metal housing |
| Dimensions (WxHxD) | P1: 250 × 228 × 50 mm |
| Connection | screw/plug terminals 2.5 mm² |
| Protection System | IP 20 |
| Weight | approx. 1,750 g |
| Disturbance test (CE) | tested according to applicable IEC standards |
| Listings | CE, UL, EAC, VDE, BDEW. CSA |
| Marine | LR (Type Approval), ABS (Type Approval) |